COVNA HK60-Q-2PS DN50 Female Thread Electric Ball Valve

Pioneers in the industry, COVNA offer electric knife gate valve, basalt line gate valve, resilient seated gate valve, resilient seated sluice valve and industrial edge gate valve. Superior grade, high efficiency, low power consumption, modular design and weather resistant best describe the quality of Motorized Knife Gate. Valves are available in wafer or lug style, as well as with cast iron bodies or stainless steel bodies

  • Model: HK60-Z-D
  • Size Range: 2'' to 16''
  • Pressure Range: 0.6MPa~2.5MPa
  • Material: Cast Iron

COVNA HK60-Q-2PS DN50 Female Thread Electric Ball Valve Features:

● The 2 piece ball size, large diameter, switch easy and convenient
● Consistent product quality and reduction of defective rate
● Reliable maintenance, sealing surface and sphere often closed state, not easy to be medium erosion
● Significant cost reduction versus competitors
● Excellent strength and toughness, easy installation
● It can be applied to water, gas, steam, oil, nitric acid, acetic acid and other media
● Cheaper and cost-efficient actuator valve for your business.

Technical Parameters of Valve Actuator
  ON/OFF Type   Feedback: the active contact signal, passive contact signal, resistance, 4-20mA
  Regulation Type   Input & Output signal: DC 4-20mA, DC 0-10V, DC 1-5V
  Field operation   The Field, Remote Control Switch Regulation and MODBUS, PROFIBUS Field Bus
  Voltage Optional   AC110-240V 380V 50/60HZ: DC12V, DC24V, Special Voltage Can be Customized
  Protection Class   IP65, Explosion Proof Construction Are Available: EX ll BT4


Technical Parameters of Valve Body
  Body   Valve components
  Size Range   DN08-DN100   Seating material   PTFE: -20℃~180℃

 

  PPL: -20℃~150℃

  Body Material   SS304, SS316, SS316L   Core Material   Stainless Steel
  End Connection   Female Thread   Stem Material   Stainless Steel
  Operating Pressure   PN1.6MPa   Applicable media   Control of water, Air, Gas, Oil, Liquid, Steam
  Structure   Floating ball core
 
 


Technical Parameter of Valve Body: 

  Nominal Size   DN15-DN200   Body Material   PVC, UPV, CPVC, PVDF and PPH
  End Connection   True Union, Double Union Thread   Structure   T Port / L Port
  Operating Pressure   1.0 / 1.6 MPa (10 / 16 bar)   Voltage Tolerance   ±10%
  Suitable Media   Corrosive media, Water, Air, etc   Temperature Of Media   -5~80℃ (23℉~176℉)
  Design standard   ISO, DIN, IDF, SMS, 3A   Orifice(mm)  15, 20, 25, 32, 40, 50, 65, 80, 100



Package & Shipping:
As a professional electric ball valve manufacturer, COVNA aims to provide our customers the best quality products with the most competitive pricing, on-time delivery and full warranty service with omprehensive service from start to finish, encompassing consultation through to after sales service, full support in every respect and ensure that you are accompanied at each stage of your project.


Company Profile:



Factory Profile:


Company Certificates:


Purchase Guide:

● Confirm the valve size you need. We offer this Female Thread Electric Ball Valve in 1/2in to 4in.

● Confirm the valve body material you need. We offer this Female Thread Electric Ball Valve in stainless steel material.

● Confirm the connection standard. We offer this Female Thread Electric Ball Valve in ANSI, JIS, DIN, and UK standard.

● Confirm the pressure and working temperature. Pressure and temperature are the important points and those may affect the cost.

● Confirm the voltage you need. The right voltage could help your valve operate better.

● Tell us your medium. Different medium has different features and we will help you to select the valve basic on the medium requirements

● Confirm the actuator type you need. We have on/off type, modulating type, intelligent type, explosion-proof type, IP68 type and auto return type electric valve actuator for your project.

Any requirements please tell us like core material, sealing material, or connection standard. We could help you to custom the valve you need.

More infomation, please send message to us. Quote will be provided within 2 hours! [email protected]

Technical Parameter of Actuators: 
  Model   5   10   16   30   60   125   250   400
  Torque Output   50Nm   100Nm   160Nm   300Nm   600Nm   1250Nm   2500Nm   4000Nm
  90°Cycle Time   20s/60s   15s/30s/60s   15s/30s   15s/30s   30s/60s   100s   100s   100s
  Angle of Rotation   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°   0-90°
  Working Current   0.25A   0.48A   0.68A   0.8A   1.2A   2A   2A   2.7A
  Starting Current   0.25A    0.48A   0.72A   0.86A   1.38A   2.3A   2.3A   3A
  Drive Motor   10W/F   25W/F   30W/F   40W/F   90W/F   100W/F   120W/F   140W/F
  Product Weight   3kg   5kg   5.5kg   8kg   8.5kg   15kg   15.5kg   16kg
  Voltage Option   AC 110V, AC 220V, AC 380V, DC 12V, DC 24V
  Insulation Resistance   DC24V:100MΩ/250V; AC110/220V/380V: 100MΩ/500V
  Withstand Voltage   DC24V:500V; AC110/220V:1500V; AC380V:1800V 1Minute
  Protection Class   IP65
  Installation Angle   Any
  Electrical Connection   G1/2 Water-proof Gable Connectors, Electric Power Wire, Signal Wire
  Ambient Temp.   -30℃to 60℃
  Control Circuit
  A: ON/OFF type with light indicator signal feedback
  B: ON/OFF type with passive contact signal feedback
  C: ON/OFF type with resistance potentiometer signal feedback
  D: ON/OFF type with resistance potentiometer and neutral position signal feedback
  E: Regulation type with servo control module
  F: DC24V/DC12V dirct ON/OFF type
  G: AC380V three-phase power supply with passive signal feedback
  H: AC380V three-phase power supply with resistance potentiometer signal feedback
Optional Function   Over Torque protectors, dehumidify heater, stainless steel coupling & yoke


3D Display of Electric Valve:

Installation Precautions:
● Before installing the valve, clean the line of dirt, scale, welding chips, and other foreign material Clean gasket surfaces thoroughly to insure leak-proof joints.
● Verify that the valve breakaway torque is less than the rated output torque of the actuator.
● Any mechanical stops that would interfere with the operation of the actuator must be removed before installation of the actuator, i.e. lever, travel stops, etc.
● The actuator output coupling must be centered with the valve stem to prevent side loading, which causes premature stem packing wear.
● To use the manual override feature (identified on cover label), the override shaft must be pressed down firmly at least 1/4" in order to disengage the motor from the gears. The manual override is not designed to overcome torque in excess of the rated torque of the actuator. Serious damage to the gear system may result from excessive turning force on the manual override.
● This Series actuator may be mounted in any position, i.e. horizontal, upside down. If the conduit entrance points upward, conduit piping must be oriented as to prevent condensation from enteringthe actuator from the conduit pipe.

Installation environment:

● The product can be installed indoor and outdoor, The surrounding environment temperature should be in -30°C~+60°C
● Product is non-explosion-proof production, and the installation must be avoided being in flammable or explosive environment etc.
● The actuator should be in protection box in the environment of long-term with the splash of rain, material and direct sunlight.
● Please reserve space for controller, manual operation.
★ The surrounding environment temperature should be in -30°C~+60°C.

Installed on the valve body:
● Manually operate the actuator to drive the valve, confirm it does not have abnormal situation. Turn the valve in full closed position.
● Assemble the bracket to the valve body.
● Set one end of couplings on valve spindle.
● Turn the electric actuator to full closing position, and insert output-input shaft into the square holes of couplings.
● Set the screw between the electric actuator and bracket.
● Turn actuator by hand shank, confirm that it moves translation, no eccentric, no skew and no overrun.


Cable installation:
● Install wire tubes, The outside diameter of wire tubes should be $9-411. Take measures to proof water. To prevent actuator from flowing into wire tubes water, the actuation position should higher than wire tubes position.
● When installing wire, the outside diameter of wire should be $9-φ11. in case the water flow into actuator interior from line locking, all wire that are not allowed to be used.
● The signal wire should be shielded wire in principle, don't parallel it to power wire.

Special tips:
● Caution: can't connect one actuator parallel with one another, in other words, can't use the same controller contact point to control more than one actuator, otherwise it will cause out of control, motor overheating, product damage, shorter service life.
If the actuator is installed outdoor, we suggest equipping other protective cover to proof water, stabilize mechanical property, make a longer service life.
 

Let’s Help